using our in-depth knowledge and vast TECHNICAL EXPERIENCE

AdobeStock 588126259
Years
0

Years of
Experience

+
0

Certified
Products

+
0

Trusted
Customers
 

Saudi Made logo.svg
Saudi Vision 2030 logo.svg
expo 2030 riyadh logo png seeklogo 516209

SFFECO continually works with certification bodies, government regulatory, partners and technology associations in efforts to provide innovative and quality products that assures accuracy in performance – from extensive product testing and evaluation and continued product quality compliance

Featured Projects

Sindala Island

We proudly supplied advanced firefighting systems and equipment to Neom’s Sindala Island, part of the Kingdom’s visionary giga-project.

View Case StudyGroup 372895

Shura Island

As part of the Red Sea development, we delivered state-of-the-art firefighting systems and equipment to Shura Island.

View Case StudyGroup 372895

Misk City

We supplied and installed modern firefighting systems and equipment to secure the landmark Misk City project.

View Case StudyGroup 372895

King Salman Park

Contributing to one of Riyadh’s most iconic urban developments, we supplied comprehensive firefighting systems and equipment for King Salman Park.

View Case StudyGroup 372895

Diriyah Gate

We provided advanced firefighting systems and equipment to Diriyah Gate projects, a world-class cultural and heritage destination.

View Case StudyGroup 372895

King Khalid International Airport

Contributing to one of Riyadh’s most iconic urban developments, we supplied comprehensive firefighting systems and equipment for King Salman Park.

View Case StudyGroup 372895

Faisaliyah Tower

We equipped Riyadh’s iconic Faisaliyah Tower with reliable firefighting systems and equipment for maximum safety.

View Case StudyGroup 372895

Riyadh Metro

Supporting one of the world’s largest metro projects, we supplied firefighting equipment to the Riyadh Metro network.

View Case StudyGroup 372895

Kingdom Tower

We delivered integrated firefighting systems and equipment to the iconic Kingdom Tower, one of Riyadh’s tallest landmarks.

View Case StudyGroup 372895

Makkah Project

We provided advanced firefighting systems and equipment to Makkah projects, contributing to the safety and protection of one of the world's most significant pilgrimage destinations and its vital infrastructure. Our scope included Fire Pump Systems, Sprinkler Systems, Clean Agent Fire Suppression Systems, and other specialized fire protection solutions designed to meet the highest safety and reliability standards.

View Case StudyGroup 372895
Sindala Island
Shura Island
Misk City
King Salman Park
Diriyah Gate
King Khalid International Airport
Faisaliyah Tower
Riyadh Metro
Kingdom Tower

Expertise

01 - 06
See AllGroup 372895
60

Product Range

Our Aim at SFFECO is to SAVE our client’s life and property from FIRE using our in-depth knowledge and vast TECHNICAL EXPERIENCE

60

Our Experience

SFFECO in its state-of-the-art manufacturing plants in Riyadh & Dubai works in close connections with renowned governmental and certification bodies to provide key answers to the challenges faced by the society.

Frequently Asked
Questions

Straight answers on extinguishers, suppression systems, pumps, hydrants, compliance and maintenance, from four decades of fire-fighting expertise.

About SFFECO

Both. SFFECO (Saudi Factory for Fire Equipment Co.) has manufactured fire-fighting equipment since 1983 in its own plants in Riyadh and Dubai, and also supplies, installs, tests and maintains complete fire protection systems.

  • Design & Manufacturing: in-house engineering and production of 600+ certified products.
  • Supply & Installation: equipment installed to approved drawings and specifications.
  • Testing, Commissioning & AMC: pre- and post-installation testing, training and ongoing maintenance.
About SFFECO

SFFECO is one of the Kingdom’s longest-established fire-fighting equipment manufacturers, with 40+ years of experience, 600+ certified products and 10,000+ customers. Its systems protect landmark projects including King Salman Park, Riyadh Metro, Kingdom Tower, Diriyah Gate, Misk City, King Khalid International Airport and NEOM’s Sindala Island.

See all projects

SFFECO is ISO 9001 certified by BRE Global Ltd., UK, and also holds ISO 14001 and ISO 45001 certifications. Individual product lines carry third-party approvals:

  • UL & FM: Prime Series clean agent systems, split case and end suction fire pumps, diesel pump drivers, and UL/FM fire hydrants.
  • LPCB & Kitemark: selected fire hydrants, semi-rigid fire hose and hose reels.
  • SASO: Excel Series fire pumps for the Saudi market.
View certificates

SFFECO’s range covers gas suppression systems, foam systems, fire pumps, fire valves, fire hydrants, fire hose cabinets, fire doors, fire extinguishers, fire-fighting vehicles and trailer units, and EV safety units, making it a one-stop shop for fire protection projects.

Explore all products

In Saudi Arabia, SFFECO has offices in Riyadh (head office and showroom), Jeddah, Dammam and Madinah. Its products reach over 100 countries through a distributor and dealer network, with design, installation, commissioning and maintenance services across the GCC, Asia, Africa and Europe.

Fire Extinguishers

Each type is rated for specific classes of fire, so choose by the hazard in the room:

  • Dry powder (ABC): general purpose for offices, warehouses and vehicles.
  • CO2: electrical equipment and flammable liquids, no residue.
  • Foam & water: ordinary combustibles; foam also covers flammable liquids.
  • Wet chemical: commercial kitchens and cooking oils (Class K).
  • Clean agent: server rooms and sensitive electronics.
Guide to extinguisher types

Under NFPA 10 there are five classes. European standards use slightly different letters, with F for cooking oils.

  • Class A: ordinary combustibles such as wood, paper and fabric.
  • Class B: flammable liquids and gases.
  • Class C: energised electrical equipment.
  • Class D: combustible metals.
  • Class K: cooking oils and fats.

An ABC (multipurpose dry powder) extinguisher is rated for Class A, B and C fires: ordinary combustibles, flammable liquids and electrical fires. It is the most common general-purpose extinguisher for offices, homes, warehouses and vehicles.

Use a CO2 or clean agent extinguisher. Both are non-conductive and leave no residue, which makes them ideal for server rooms, switch rooms and electrical panels. An ABC powder extinguisher also works but leaves residue. Never use water or foam on live electrical equipment.

Remember PASS: Pull the safety pin, Aim the nozzle at the base of the fire, Squeeze the handle, and Sweep from side to side until the fire is out. Keep a clear exit behind you, stand 2 to 3 metres back, and leave immediately if the fire grows.

Extinguishers do not have a single expiry date, but they must pass regular checks to stay in service. NFPA 10 calls for:

  • Monthly: visual inspection of pressure, seals and access.
  • Annually: maintenance by a qualified technician.
  • Every 5 or 12 years: hydrostatic pressure testing, depending on the type.

Replace any unit that is damaged, corroded or fails a test.

NFPA inspection schedule

An extinguisher must be recharged after every use, even partial use, and whenever the gauge needle is outside the green zone. SFFECO’s service teams refill, recharge and maintain extinguishers from branches in Riyadh, Jeddah, Dammam and Madinah.

Suppression Systems

A fire suppression system detects and extinguishes a fire automatically, usually by discharging a clean agent gas, CO2, foam, water mist or wet chemical into the protected area. It is used where water would damage equipment or a fire must be controlled within seconds, such as data centres, control rooms, archives and kitchens.

Fire protection lifecycle
  • Clean agent: HFC-227ea (FM-200) and FK-5-1-12, for occupied spaces with sensitive equipment.
  • CO2: for normally unoccupied machinery and electrical spaces.
  • Foam: for flammable liquid hazards such as fuel storage and hangars.
  • Water mist: low water use with strong cooling.
  • Wet chemical: for commercial kitchen hoods.

FM-200 is the trade name for HFC-227ea (heptafluoropropane), a colourless clean agent stored as a liquefied gas. It puts out fire mainly by absorbing heat, typically within 10 seconds, and leaves no residue. At the design concentrations in NFPA 2001 it is considered safe for occupied spaces. SFFECO’s UL and FM approved Prime Series 227 uses HFC-227ea; the Prime Series 5112 uses FK-5-1-12 for projects that need a lower environmental impact.

NFPA 2001 clean agent guide

Clean agent systems are safe for occupied areas and protect sensitive electronics without residue. CO2 systems are very effective and cost-efficient but are hazardous to people at extinguishing concentrations, so they are reserved for normally unoccupied spaces such as machinery rooms, turbine enclosures and electrical vaults.

Clean agent vs CO2
Sprinklers & Pumps

Each sprinkler head is sealed by a heat-sensitive glass bulb or fusible link. When the air around it reaches the rated temperature, commonly about 68°C, that head opens and sprays water onto the fire. Only the heads near the fire activate, which controls the fire quickly while limiting water damage.

  • Wet pipe: water stays in the pipes; the most common type.
  • Dry pipe: pressurised air in the pipes, for areas that may freeze.
  • Pre-action: needs a detection signal before water enters the pipes; protects sensitive areas.
  • Deluge: open heads discharge together, for high hazards like transformers and fuel stores.

A fire pump boosts water pressure and flow from a tank or mains supply so sprinklers, hydrants and hose reels perform as designed. A typical package combines a main electric pump, a diesel standby pump and a small jockey pump that keeps the system pressurised, designed to NFPA 20.

All fire pumps

Saudi Aramco projects generally specify fire pumps that are UL listed and/or FM approved and comply with NFPA 20 together with Aramco’s own engineering standards. SFFECO’s split case and end suction pumps and diesel engine drivers carry UL and FM certificates. Always confirm the exact requirements in your project specification.

Talk to our pump team
Hydrants & Hose Reels

A fire hydrant is an outdoor connection to a pressurised water main that fire brigades and site teams use to supply hoses and fire trucks. The two main types are:

  • Wet barrel: water is always in the hydrant body, suited to warm climates like the GCC.
  • Dry barrel: the valve sits below ground and water enters only when opened, for freezing climates.
All fire hydrants

A fire hose reel is a wall-mounted length of semi-rigid hose connected to the water supply, usually housed in a fire cabinet, for first response by building occupants. Open the valve, run out the hose toward the fire, then open the nozzle and aim at the base of the flames. Hose reels are for Class A fires only, never electrical or flammable-liquid fires.

All fire cabinets

A landing valve is an outlet on a building’s wet or dry riser, usually on each floor or stair landing, where firefighters connect their hoses. Common styles include oblique, right-angle and straight-through valves, typically housed in a landing valve cabinet.

Compliance & Maintenance

Requirements depend on a building’s occupancy, height, area and use, and are set by the Saudi Building Code (SBC 801 Fire Code) and enforced by the General Directorate of Civil Defense. High-rise, commercial, industrial, healthcare and assembly buildings typically need automatic sprinklers, fire pumps and standpipe or hose systems. A qualified fire protection designer should confirm the requirements for your project.

NFPA 25 sets the schedule for water-based systems:

  • Weekly to monthly: visual checks of valves, gauges and fire pump churn tests.
  • Quarterly: alarm devices and waterflow checks.
  • Annually: full system inspection and fire pump flow test.
  • Every 3 to 5 years: internal pipe checks and specific component tests.

Suppression systems and extinguishers follow NFPA 2001 and NFPA 10.

Full NFPA 25 schedule

An Annual Maintenance Contract (AMC) is a yearly agreement covering scheduled inspections, testing and preventive maintenance of your fire protection equipment, so it stays compliant and ready to work. SFFECO offers AMCs for all fire safety equipment, with regular site visits to check every installed device.

AMC vs reactive maintenance

Didn't find your answer?

Our engineers in Riyadh, Jeddah, Dammam and Madinah can help with product selection, approvals and project specifications.

Showcasing
Security Innovation
at Intersec KSA

SFFECO continually expands upon its knowledge and services to keep its clients updated with the latest Fire Fighting Technology in the world. The product range manufactured by SFFECO confirms and holds approval to international standards

Product Range

Our Projects

Services

Fire Extinguisher Image from far

We supply a wide range of reliable fire extinguishers designed to provide quick and effective first response in case of fire emergencies.

SFFECO Fire Cabinet Range

We provide durable fire cabinets designed to securely store and protect firefighting equipment for quick and easy access during emergencies.

Range of Fire Pump by SFFECO

We offer reliable fire pumps engineered to ensure consistent water pressure and dependable performance for effective firefighting operations.

Fire Doors by SFFECO

We supply certified fire doors and frames designed to contain fire and smoke, providing safety and protection in buildings during emergencies.

SFFECO Foam Spray Equipment

We provide advanced foam firefighting equipment designed to effectively suppress flammable liquid fires and enhance fire safety response.

SFFECO Fire Valves Range

We offer high-quality fire valves designed to control and regulate water flow, ensuring reliable performance in firefighting systems.

SFFECO supplied advanced firefighting systems and equipment to Neom’s Sindala Island

We proudly supplied advanced firefighting systems and equipment to Neom’s Sindala Island, part of the Kingdom’s visionary giga-project.

SFFECO supplied advanced firefighting systems and equipment to Shura Island

As part of the Red Sea development, we delivered state-of-the-art firefighting systems and equipment to Shura Island.

SFFECO delivered modern firefighting systems and equipment to secure the landmark Misk City project

We supplied and installed modern firefighting systems and equipment to secure the landmark Misk City project.

Sffeco delivered firefighting systems and equipment for King Salman Park

Contributing to one of Riyadh’s most iconic urban developments, we supplied comprehensive firefighting systems and equipment for King Salman Park.

SFFECO provided advanced firefighting systems and equipment to Diriyah Gate projects

We provided advanced firefighting systems and equipment to Diriyah Gate projects, a world-class cultural and heritage destination.

SFFECO supplied firefighting equipment to the Riyadh Metro network

Supporting one of the world’s largest metro projects, we supplied firefighting equipment to the Riyadh Metro network.

Saudi Arabia Skyline

We delivered integrated firefighting systems and equipment to the iconic Kingdom Tower, one of Riyadh’s tallest landmarks.

SFFECO supplied comprehensive firefighting systems and equipment for King Salman Park

Contributing to one of Riyadh’s most iconic urban developments, we supplied comprehensive firefighting systems and equipment for King Salman Park.

Fire equipment engineered and built in-house.

Supplied and installed to approved drawings.

Fire system testing and commissioning

Tested and verified for Civil Defense handover.

Fire-Protection-System-Maintenance